TC-300R8
|
Industrial 300W Hot
Swap Redundant Power
Supply |
| Features |
- TEMPERATURE RANGE : Operation
0oC~50oC
- HOLD UP TIME : 16ms at
maximum load & normal input voltage
- EFFICIENCY : 68% TYPICAL
(Normal Line)
- POWER GOOD SIGNAL: Should be
asserted high to indicate that+5VDC and +3.3VDC output are above
the low voltage thresholds. Compatible signal out with 100ms to
500ms.
- OVER POWER PROTECTION : The
power supply shall shout down output power exceeds 130% to 160%
- OVER VOLTAGE PROTECTION :
Standard on +5.0V, set at 6.25VDC ± 0.75VDC
- SHORT CIRCUIT PROTECTION: A
short circuit placed between the DC return and the output shall
cause no damage and the power supply shall shutdown.
- EMI: FCC part 15, subpart B,
Class B, EN55022 CISPR22 Class B.
- APPROVALS :UL60950,
CAN/CSA22.2 No.60950, TUV(IEC60950)
REMOTE ON/OFF CONTROL: When PS-ON is pulled to TTL Low, the DC
output is to be enabled, When PS-OFF is pulled to TTL high, the
DC output is to disabled.
- COOLING : By forced air
2x40mm Fan (Each module)
- DIMENSION: L199 X W150 X H86
mm
|
|
|
 |
Ordering Information
|
TC-300R8 |
Industrial 300W Hot
Swap Redundant Power
Supply |
|
|
|
 |
TC-400R8
|
Industrial 400W Hot
Swap Redundant Power
Supply |
| Features |
- TEMPERATURE RANGE : Operation
0oC~50oC
- HOLD UP TIME : 16ms at
maximum load & normal input voltage
- EFFICIENCY : 68% TYPICAL
(Normal Line)
- POWER GOOD SIGNAL: Should be
asserted high to indicate that+5VDC and +3.3VDC output are above
the low voltage thresholds. Compatible signal out with 100ms to
500ms.
- OVER POWER PROTECTION : The
power supply shall shout down output power exceeds 130% to 160%
- OVER VOLTAGE PROTECTION :
Standard on +5.0V, set at 6.25VDC ± 0.75VDC
- SHORT CIRCUIT PROTECTION: A
short circuit placed between the DC return and the output shall
cause no damage and the power supply shall shutdown.
- EMI: FCC part 15, subpart B,
Class B, EN55022 CISPR22 Class B.
- APPROVALS :UL60950,
CAN/CSA22.2 No.60950, TUV(IEC60950)
REMOTE ON/OFF CONTROL: When PS-ON is pulled to TTL Low, the DC
output is to be enabled, When PS-OFF is pulled to TTL high, the
DC output is to disabled.
- COOLING : By forced air
2x40mm Fan (Each module)
- DIMENSION: L199 X W150 X H86
mm
|
|
|
 |
Ordering Information
|
TC-400R8 |
Industrial 400W Hot
Swap Redundant Power
Supply |
|
|
|
 |
TC-300R8A
|
Industrial 300W Hot
Swap Redundant Power
Supply |
| Features |
- TEMPERATURE RANGE : Operation
0oC~50oC
- HOLD UP TIME : 16ms at
maximum load & normal input voltage
- EFFICIENCY : 68% TYPICAL
(Normal Line)
- POWER GOOD SIGNAL: Should be
asserted high to indicate that+5VDC and +3.3VDC output are above
the low voltage thresholds. Compatible signal out with 100ms to
500ms.
- OVER POWER PROTECTION : The
power supply shall shout down output power exceeds 130% to 160%
- OVER VOLTAGE PROTECTION :
Standard on +5.0V, set at 6.25VDC ± 0.75VDC
- SHORT CIRCUIT PROTECTION: A
short circuit placed between the DC return and the output shall
cause no damage and the power supply shall shutdown.
- EMI: FCC part 15, subpart B,
Class B, EN55022 CISPR22 Class B.
- APPROVALS :UL60950,
CAN/CSA22.2 No.60950, TUV(IEC60950)
REMOTE ON/OFF CONTROL: When PS-ON is pulled to TTL Low, the DC
output is to be enabled, When PS-OFF is pulled to TTL high, the
DC output is to disabled.
- COOLING : By forced air
2x40mm Fan (Each module)
- DIMENSION: L199 X W150 X H86
mm
|
|
|
 |
Ordering Information
|
TC-300R8A |
Industrial 300W Hot
Swap Redundant Power
Supply |
|
|
|
 |
TC-400R8A
|
Industrial 400W Hot
Swap Redundant Power
Supply |
| Features |
- TEMPERATURE RANGE : Operation
0oC~50oC
- HOLD UP TIME : 16ms at
maximum load & normal input voltage
- EFFICIENCY : 68% TYPICAL
(Normal Line)
- POWER GOOD SIGNAL: Should be
asserted high to indicate that+5VDC and +3.3VDC output are above
the low voltage thresholds. Compatible signal out with 100ms to
500ms.
- OVER POWER PROTECTION : The
power supply shall shout down output power exceeds 130% to 160%
- OVER VOLTAGE PROTECTION :
Standard on +5.0V, set at 6.25VDC ± 0.75VDC
- SHORT CIRCUIT PROTECTION: A
short circuit placed between the DC return and the output shall
cause no damage and the power supply shall shutdown.
- EMI: FCC part 15, subpart B,
Class B, EN55022 CISPR22 Class B.
- APPROVALS :UL60950,
CAN/CSA22.2 No.60950, TUV(IEC60950)
REMOTE ON/OFF CONTROL: When PS-ON is pulled to TTL Low, the DC
output is to be enabled, When PS-OFF is pulled to TTL high, the
DC output is to disabled.
- COOLING : By forced air
2x40mm Fan (Each module)
- DIMENSION: L199 X W150 X H86
mm
|
|
|
 |
Ordering Information
|
TC-400R8A |
Industrial 400W Hot
Swap Redundant Power
Supply |
|
|
|
 |
TC-500R8A
|
Industrial 500W Hot
Swap Redundant Power Supply |
| Features |
- TEMPERATURE RANGE : Operation
0oC~50oC
- HOLD UP TIME : 16ms at
maximum load & normal input voltage
- EFFICIENCY : 68% TYPICAL
(Normal Line)
- POWER GOOD SIGNAL: Should be
asserted high to indicate that+5VDC and +3.3VDC output are above
the low voltage thresholds. Compatible signal out with 100ms to
500ms.
- OVER POWER PROTECTION : The
power supply shall shout down output power exceeds 130% to 160%
- OVER VOLTAGE PROTECTION :
Standard on +5.0V, set at 6.25VDC ± 0.75VDC
- SHORT CIRCUIT PROTECTION: A
short circuit placed between the DC return and the output shall
cause no damage and the power supply shall shutdown.
- EMI: FCC part 15, subpart B,
Class B, EN55022 CISPR22 Class B.
- APPROVALS :UL60950,
CAN/CSA22.2 No.60950, TUV(IEC60950)
REMOTE ON/OFF CONTROL: When PS-ON is pulled to TTL Low, the DC
output is to be enabled, When PS-OFF is pulled to TTL high, the
DC output is to disabled.
- COOLING : By forced air
2x40mm Fan (Each module)
- DIMENSION: L199 X W150 X H86
mm
|
|
|
 |
Ordering Information
|
TC-500R8A |
Industrial 500W Hot
Swap Redundant Power
Supply |
|
|
|
|
|
|
|